Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 11(9): e0162346, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27598005

RESUMO

AIM: In this work we estimated the contribution of the fluorescence of 4-pyridoxic acid (4-PA) to the total fluorescence of spent dialysate with the aim of evaluating the on-line monitoring of removal of this vitamin B-6 metabolite from the blood of patients with end-stage renal disease (ESRD). METHODS: Spectrofluorometric analysis of spent dialysate, collected from hemodialysis and hemodiafiltration sessions of 10 patients receiving regularly pyridoxine injections after dialysis treatment, was performed in the range of Ex/Em 220-500 nm. 4-PA in dialysate samples was identified and quantified using HPLC with fluorescent and MS/MS detection. RESULTS: Averaged HPLC chromatogram of spent dialysate had many peaks in the wavelength region of Ex320/Em430 nm where 4-PA was the highest peak with contribution of 42.2±17.0% at the beginning and 47.7±18.0% in the end of the dialysis. High correlation (R = 0.88-0.95) between 4-PA concentration and fluorescence intensity of spent dialysate was found in the region of Ex310-330/Em415-500 nm, respectively. CONCLUSION: 4-PA elimination from the blood of ESRD patients can be potentially followed using monitoring of the fluorescence of the spent dialysate during dialysis treatments.


Assuntos
Hemodiafiltração , Falência Renal Crônica/sangue , Ácido Piridóxico/sangue , Deficiência de Vitamina B 6/sangue , Vitamina B 6/sangue , Idoso , Biotransformação , Cromatografia Líquida de Alta Pressão , Soluções para Diálise , Feminino , Fluorescência , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Espectrometria de Fluorescência , Vitamina B 6/administração & dosagem , Vitamina B 6/farmacocinética , Deficiência de Vitamina B 6/complicações , Deficiência de Vitamina B 6/diagnóstico , Deficiência de Vitamina B 6/terapia
2.
Int J Artif Organs ; 38(6): 311-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26109264

RESUMO

PURPOSE: The aim of the study was to explore the possibility of assessing lean body mass (LBM) based on UV absorbance measurements in spent dialysate. METHODS: 9 patients on chronic three-times-a-week HD (4 female, 5 male, mean age 58.8 ± 8.6 years) were studied. Blood and spent dialysate samples were collected for 3 consecutive hemodialysis (HD) sessions from every patient. A double-beam spectrophotometer was used for the determination of UV absorbance in the collected spent dialysate samples. Dual-energy x-ray absorptiometry (DXA) scans were performed on an interdialytic day. LBM was calculated based on creatinine concentration in blood (LBMblood) and UV absorbance in spent dialysate (LBMa) and assessed by DXA (LBMDXA). Also, in vitro experiments were carried out to investigate the effect of tissue hydration on DXA measurements. RESULTS: Although LBMa was slightly lower compared to LBMblood, the estimates based on UV absorbance in spent dialysate presented greater accuracy and precision compared to LBMDXA. The significant difference between LBMblood and LBMDXA was with high probability caused by the altered tissue hydration of HD patents. CONCLUSIONS: In summary, the results show that it is possible to asses LBM based on UV absorbance in spent dialysate.


Assuntos
Composição Corporal/fisiologia , Falência Renal Crônica/terapia , Diálise Renal , Absorciometria de Fóton , Idoso , Soluções para Diálise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espectrofotometria Ultravioleta
3.
ASAIO J ; 60(4): 459-65, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24814831

RESUMO

The aim of the study was to examine the possibility of postdialysis urea rebound assessment using UV-absorbance measurements in spent dialysate. Twenty-six patients on chronic three-times-a-week hemodialysis (HD) were studied in two separate studies. Double-beam spectrophotometer was used for the determination of UV absorbance in the collected spent dialysate samples. Also, on-line UV absorbance was monitored. The equilibrium concentration (C(eq)) of urea at the end of the rebound phase was calculated based on urea concentration in blood and dialysate and UV absorbance in spent dialysate. Based on C(eq), urea rebound was expressed relative to urea concentration at the end of HD (R1) and relative to the decrease in urea concentration during HD (R2). Estimates based on UV-absorbance values in spent dialysate (R(1_a), R(2_a)) slightly over assess postdialysis rebound compared with results based on the blood sample drawn 30 min after HD (R(1_30post), R(2_30post)), but R(1_a) and R(2_a) presented greater consistency and accuracy compared with the estimates based on the intradialytic blood sample (R(1_b), R(2_b)). In summary, the results show that it is possible to assess postdialysis urea rebound in blood based on UV-absorbance measurements in spent dialysate.


Assuntos
Soluções para Diálise/química , Diálise Renal , Espectrofotometria Ultravioleta/métodos , Ureia/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Soluções para Diálise/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
4.
Clin Nephrol ; 79(2): 107-17, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23110769

RESUMO

AIM: The aim of the study was to develop an optical method for the estimation of creatinine (Cr) removal during dialysis using UV-absorbance. MATERIAL AND METHODS: 29 hemodialysis patients on chronic 3-times-a-week hemodialysis were studied in 6 separate studies. Double-beam pectrophotometer was used for the determination of UV-absorbance in the collected spent dialysate samples. A single wavelength (SW) and a multi-wavelength (MW) model were developed using stepwise regression utilizing Cr values from the laboratory as the dependent parameter. The reduction ratio (RR) and total removed Cr (TRCr) were estimated. RESULTS: For blood-Cr RRb (mean ± SD) was 60.9 ± 5.0% (calibration set) and 58.1 ± 6.0% (validation set), for SW UVabsorbance RR_SW was 61.5 ± 5.9% and 57.3 ± 6.0%, and for MW UV-absorbance RR_MW was 65.8 ± 5.8% and 61.7 ± 6.4% respectively. RR_SW and RRb were not statistically different. RR_MW was higher compared to RRb (p < 0.05). TRCr_lab was 13.8 ± 3.8 mmol, TRCr_SW 14.5 ± 2.5 mmol and TRCr_MW 13.8 ± 2.6 mmol, being not statistically different. CONCLUSION: In summary, creatinine removal during dialysis can be estimated as reduction ratio and total removed creatinine with the UV-absorbance technique.


Assuntos
Creatinina/análise , Soluções para Diálise/química , Diálise Renal/métodos , Espectrofotometria Ultravioleta/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Calibragem , Creatinina/sangue , Creatinina/química , Humanos , Pessoa de Meia-Idade , Análise de Regressão , Reprodutibilidade dos Testes , Ácido Úrico/análise , Ácido Úrico/química
5.
Int J Radiat Biol ; 84(1): 69-79, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18058332

RESUMO

PURPOSE: The aim of this study was to evaluate the effect of microwaves modulated at different frequencies on human electroencephalographic (EEG) rhythms. MATERIALS AND METHODS: Thirteen healthy volunteers were exposed to microwaves (450 MHz) pulse-modulated at frequencies of 7, 14 and 21 Hz. The field power density at the scalp was 0.16 mW/cm2. Our experimental protocol consisted of two five-cycle (1 min on and 1 min off) series of exposures at fixed modulation frequencies. A relative change in the EEG power with and without exposure was used as a quantitative measure. EEG frequencies recorded in the theta (4-6.8 Hz), alpha (8-13 Hz), betal (15-20 Hz), and beta2 (22-38 Hz) bands were analyzed. RESULTS: Modulated microwaves caused an increase in the average EEG alpha (17%) and beta (7%) power but the theta rhythm remained unaffected. Increases in the EEG alpha and beta power were statistically significant during the first half-period of the exposure interval (30 s) at the modulation frequencies of 14 and 21 Hz. Differences were found in individual sensitivity to exposure. Increases in the EEG beta power appeared statistically significant in the case of four subjects. CONCLUSIONS: Our findings suggest that the effect of the 450 MHz microwave radiation modulated at 7, 14 and 21 Hz varies depending on the modulation frequency. The microwave exposure modulated at 14 and 21 Hz enhanced the EEG power in the alpha and beta frequency bands, whereas no enhancement occurred during exposure to the modulation frequency of 7 Hz.


Assuntos
Encéfalo/efeitos da radiação , Eletroencefalografia , Micro-Ondas/efeitos adversos , Adulto , Ritmo alfa , Ritmo beta , Encéfalo/fisiologia , Feminino , Humanos , Masculino
6.
Artigo em Inglês | MEDLINE | ID: mdl-18003066

RESUMO

The experiments of adaptation of the human brain bioelectrical activity were carried out on a group of 14 healthy volunteers exposed to 450 MHz microwave radiation modulated at 40 Hz frequencies. The field power density at the scalp was 0.16 mW/cm(2). Results of the study indicate that adaptation effect of human brain to low-level microwave exposure is evident. The initial increase of EEG power was compensated and even overcompensated. The adaptation phenomena were obvious in EEG alpha and beta rhythms..


Assuntos
Encéfalo/fisiologia , Eletroencefalografia , Micro-Ondas , Adulto , Ritmo alfa , Ritmo beta , Encéfalo/efeitos da radiação , Feminino , Humanos , Entrevistas como Assunto , Masculino , Tempo de Reação , Inquéritos e Questionários
7.
Nonlinear Biomed Phys ; 1(1): 9, 2007 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-17908286

RESUMO

The aim of this study was to select and evaluate methods sensitive to reveal small hidden changes in the electroencephalographic (EEG) signal. Two original methods were considered.Multifractal method of scaling analysis of the EEG signal based on the length distribution of low variability periods (LDLVP) was developed and adopted for EEG analysis. The LDLVP method provides a simple route to detecting the multifractal characteristics of a time-series and yields somewhat better temporal resolution than the traditional multifractal analysis.The method of modulation with further integration of energy of the recorded signal was applied for EEG analysis. This method uses integration of differences in energy of the EEG segments with and without stressor.Microwave exposure was used as an external stressor to cause hidden changes in the EEG. Both methods were evaluated on the same EEG database. Database consists of resting EEG recordings of 15 subjects without and with low-level microwave exposure (450 MHz modulated at 40 Hz, power density 0.16 mW/cm2). The significant differences between recordings with and without exposure were detected by the LDLVP method for 4 subjects (26.7%) and energy integration method for 2 subjects (13.3%).The results show that small changes in time variability or energy of the EEG signals hidden in visual inspection can be detected by the LDLVP and integration of differences methods.

8.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 1597-600, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17946053

RESUMO

Three different methods in combination with integration of differences in signals were applied for EEG analysis to distinguish changes in EEG caused by microwave: S-parameter, power spectral density and length distribution of low variability periods. The experiments on the effect of modulated low-level microwaves on human EEG were carried out on four different groups of healthy volunteers exposed to 450 MHz microwave radiation modulated with 7 Hz, 14 Hz, 21 Hz, 40 Hz, 70 Hz, 217 or 1000 Hz frequencies. The field power density at the scalp was 0.16 mW/cm2. The EEG analysis performed for individuals with three different methods showed that statistically significant changes occur in the EEG rhythms energy and dynamics between 12% and 30% of subjects.


Assuntos
Relógios Biológicos/fisiologia , Encéfalo/fisiologia , Encéfalo/efeitos da radiação , Eletroencefalografia/métodos , Potenciais Evocados/fisiologia , Micro-Ondas , Adulto , Relógios Biológicos/efeitos da radiação , Relação Dose-Resposta à Radiação , Potenciais Evocados/efeitos da radiação , Feminino , Humanos , Masculino , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...